Regulatory Document RD-327, Nuclear Criticality Safety provides requirements for the prevention of criticality accidents in the handling, storage, processing, and transportation of fissionable materials and the long-term management of nuclear waste. This regulatory document clarifies the physical constraints and limits on fissionable materials that licensees must implement in order to ensure nuclear criticality safety during the construction, operation, decommissioning, or abandonment of the licensed facility. This document also includes requirements for alarms and shielding in areas to minimize the dose if a criticality accident does occur.
This document presents CNSC’s requirements regarding nuclear criticality safety. The associated guidance document GD-327, Guidance for Nuclear Criticality Safety, provides information as to how these requirements may be met.
This regulatory document applies to operations with fissionable materials outside nuclear reactors, except for the assembly of these materials under controlled conditions (such as in critical experiments).
Key principles and elements used in developing this document and the associated guidance document are consistent with national and international standards.
Nothing contained in this document is to be construed as relieving any licensee from pertinent requirements. It is the licensee’s responsibility to identify and comply with all applicable regulations and licence conditions.
If any discrepancies exist between this regulatory document and guidance document GD-327, Guidance for Nuclear Criticality Safety, then the information in this regulatory document RD-327, Nuclear Criticality Safety takes precedence.
2.3.1.1 Exempted quantity of fissionable materials
2.3.1.2 Small quantity of fissionable materials
2.3.1.3 Large quantity of fissionable materials
2.3.1.4 Nuclear criticality safety program relative to categorization
4.0 Use of Borosilicate-Glass Raschig Rings as a Neutron Absorber in Solutions of Fissile Material
5.0 Safety in Conducting Subcritical Neutron Multiplication Measurements In Situ
6.0 Nuclear Criticality Safety in the Storage of Fissile Materials
7.0 Criteria for Nuclear Criticality Safety Controls in Operations with Shielding and Confinement
8.0 Nuclear Criticality Control and Safety of Plutonium-Uranium Fuel Mixtures Outside Reactors
9.0 Use of Soluble Neutron Absorbers in Nuclear Facilities Outside Reactors
10.0 Nuclear Criticality Control of Special Actinide Elements
12.0 Administrative Practices for Nuclear Criticality Safety
12.5 Process evaluation for nuclear criticality safety (nuclear criticality safety evaluation)
13.0 Nuclear Criticality Safety Training
14.0 Use of Fixed Neutron Absorbers in Nuclear Facilities Outside Reactors
15.0 Nuclear Criticality Safety Based on Limiting and Controlling Moderators
16.0 Nuclear Criticality Accident Emergency Planning and Response
Appendix A: Normal and Credible Abnormal Conditions
This regulatory document provides requirements for the prevention of criticality accidents in the handling, storage, processing, and transportation of fissionable materials and the long-term management of nuclear waste.
This regulatory document clarifies the physical constraints and limits on fissionable materials that the licensee must implement in order to ensure nuclear criticality safety during the construction, operation, decommissioning, or abandonment of the licensed facility. This document also includes requirements for alarms and shielding to minimize the dose if a criticality accident does occur.
This regulatory document presents CNSC’s requirements regarding nuclear criticality safety. The associated guidance document GD-327, Guidance for Nuclear Criticality Safety [1], provides information as to how these requirements may be met.
This regulatory document applies to operations with fissionable materials outside nuclear reactors, except for the assembly of these materials under controlled conditions (such as in critical experiments).
If any discrepancies exist between this regulatory document and guidance document GD-327, Guidance for Nuclear Criticality Safety, then the information in this regulatory document RD-327, Nuclear Criticality Safety takes precedence.
The provisions of the Nuclear Safety and Control Act (NSCA; this Act) and the regulations made under the NSCA relevant to this regulatory document are as follows:
The Nuclear Fuel Waste Act and the Nuclear Liability Act may also apply to operations with fissionable materials.
Key principles and elements used in developing this regulatory document are consistent with national and international standards.
In particular, some sections of this regulatory document are extracted from the following standards from the American National Standards Institute (ANSI), with permission of the publisher, the American Nuclear Society (ANS). Where necessary, the text has been adapted to make it applicable to Canada’s international obligations to the International Atomic Energy Agency (IAEA) and consistent with CNSC’s regulatory requirements.
In addition, this regulatory document is consistent with:
Operations with some fissionable materials introduce risks of a criticality accident resulting in a release of radiation that can be lethal to nearby personnel. However, experience has shown that extensive operations can be performed safely and economically when proper precautions are exercised.
Generalized basic criteria are presented and limits are specified for 233U, 235U, or 239Pu.
This section does not include the details of administrative controls, the design of processes or equipment, the description of instrumentation for process control, nor detailed criteria to be met in transporting fissionable materials.
Operations with fissionable materials shall meet the requirements of this regulatory document.
2.3.1.1 Exempted quantity of fissionable materials
An exempted quantity of fissionable materials in the licensed site is defined as an inventory of fissionable materials, as follows:
Licensed sites operating with exempted quantities of fissionable materials are exempt from the requirements of this regulatory document.
2.3.1.2 Small quantity of fissionable materials
A small quantity of fissionable materials in the licensed site is defined as an inventory of fissionable materials, which:
This regulatory document is partially applicable, as further specified in section 2.3.1.4, to licensed sites operating with small quantities of fissionable materials.
2.3.1.3 Large quantity of fissionable materials
A large quantity of fissionable materials in the licensed site is defined as an inventory of fissionable materials that exceeds the limits listed in section 2.3.1.2.
This regulatory document is applicable to licensed sites operating with large quantities of fissionable materials.
Note that a licensed site containing a large quantity of fissionable materials may be subject to the Nuclear Liability Act.
2.3.1.4 Nuclear criticality safety program relative to categorization
A nuclear criticality safety program shall be developed and maintained in the licensed site to meet the CNSC nuclear criticality safety requirements and to support its safe operation. The extent of the program depends on the category of operations with fissionable materials:
Management shall clearly establish responsibility for nuclear criticality safety. Supervisors should be made as responsible for nuclear criticality safety as they are for production, development, research, or other functions. Each individual, regardless of position, shall be made aware that nuclear criticality safety in their work area is ultimately their responsibility. This may be accomplished through training and periodic retraining of all operating and support personnel.
Management shall provide personnel skilled in the interpretation of data pertinent to nuclear criticality safety, and familiar with operations, to serve as advisors to supervisors. These specialists should be, to the extent practicable, administratively independent of process supervisors.
Management shall establish the criteria to be satisfied by nuclear criticality safety controls. Distinction may be made between shielded and unshielded facilities, and the criteria may be less stringent when adequate shielding and confinement assure the protection of personnel.
Before a new operation with fissionable material is begun, or before an existing operation is changed, it shall be determined that the entire process will be subcritical under both normal and credible abnormal conditions that have frequency of occurrence equal to or greater than 10-6 per year [6, 7]. Examples of such conditions are given in Appendix A.
Operations to which nuclear criticality safety is pertinent shall be governed by written procedures.
All persons participating in these operations shall understand and be familiar with the procedures.
The procedures shall specify all parameters that they are intended to control. They should be such that no single, inadvertent departure from a procedure can cause a criticality accident.
The movement of fissionable material shall be controlled. Appropriate material labelling, signs, and area posting shall be maintained specifying material identification and all limits on parameters subject to procedural control.
Prior to starting a new or modified process or processing line, it shall be ascertained that all equipment is consistent in dimension and material with the assumptions made to ensure subcriticality [8].
2.3.2.6 Quality management program
A quality management (QM) program that meets the applicable requirements of ANSI/ASME NQA-1-2008, Quality Assurance Requirements for Nuclear Facility Applications [12], CSA N286-05, Management system requirements for nuclear power plants [13], or equivalent, shall be established to implement the activities specified in this regulatory document.
Records shall be maintained according to the QM program to demonstrate that the facility and its equipment were constructed according to the design specifications. The licensee shall define a formal design change procedure as part of their QM program, so that all modifications made to the facility or to the facility’s processes or procedures during all stages of the life cycle are accurately recorded and their impact assessed with respect to nuclear criticality safety [2]. These QM measures are expected to be an integral part of the site’s overall QM program.
Deviations from procedures and unforeseen alterations in process conditions that affect nuclear criticality safety shall be reported to management and shall be investigated promptly. When available, the information about incidents and events in other installations of the same type shall also be investigated and lessons learnt shall be considered. Possible improvements in criticality safety practices or equipment shall be considered and action shall be taken to prevent recurrence [2, 8].
Operations shall be reviewed frequently (at least annually) to verify that procedures are being followed and that process conditions have not been altered in any way that would affect the applicable nuclear criticality safety evaluation (NSCE). These reviews shall be conducted in consultation with operating personnel, by individuals who are knowledgeable in nuclear criticality safety and who, to the extent practicable, are not immediately responsible for the operation.
Emergency procedures shall be prepared and approved by management. On-site and off-site organizations that are expected to respond to emergencies shall be made aware of conditions that might be encountered, and they should be assisted in preparing suitable procedures governing their responses.
All controlled parameters and their limits shall be specified. The influence of variations in these parameters on the keff of the system shall be understood.
2.3.3.2 Availability and reliability
The licensee shall ensure that the necessary levels of availability and reliability are maintained for nuclear criticality safety controls, as established by the process analysis for normal and credible abnormal conditions.
The following principles shall be incorporated as appropriate to attain the required availability and reliability of engineered nuclear criticality safety controls [2].
Double contingency principle
Process designs should incorporate sufficient factors of safety to require at least two unlikely, independent, and concurrent changes in process conditions before a criticality accident is possible.
Testability
All engineered nuclear criticality safety controls shall be designed and arranged so that:
If it is not practicable to provide adequate testability of a component, the safety analysis should take into account the possibility of undetected failures of such equipment [2].
Where practicable, reliance should be placed on equipment design in which dimensions are limited rather than on administrative controls. Full advantage may be taken of any nuclear characteristics of the process materials and equipment. All dimensions and nuclear properties on which reliance is placed shall be verified prior to the beginning of operations, and control shall be exercised to maintain them.
Where applicable data are available, subcritical limits shall be established on bases derived from experiments, with adequate allowance for uncertainties in the data. In the absence of directly applicable experimental measurements, the limits may be derived from calculations made by a method shown by comparison with experimental data to be valid in accordance with section 2.3.4.
Where applicable, neutron reflection shall be considered as a parameter for criticality control. The most effective neutron reflector commonly encountered in handling and in processing fissionable material is water of thickness sufficient to yield maximum nuclear reactivity. However, careful consideration shall be given to systems where significant thicknesses of other common structural materials (e.g., wood, concrete, steel), which may be more effective neutron reflectors than water, may be present. For some situations, the reflection provided by personnel may be important [8] (the material content of the human body can provide significant moderating capability [refer to GD-327, Guidance for Nuclear Criticality Safety [1], Appendix F]).
Consideration shall be given to neutron interaction between units when at least two units containing fissionable material are present. It is possible to reduce neutron interaction to acceptable proportions either by spacing units, by insertion of suitable neutron-moderating and absorbing materials between units, or by some combination of these methods [8].
Suitable calculational methods for determining the subcritical state of a system shall be selected and justified in accordance with an applicable quality assurance standard. The methods vary widely in basis and form, and each has its place in the broad spectrum of situations encountered in the nuclear criticality safety field. However, the general procedure to be followed in establishing validity is common to all. For an example of validation of a calculational method, refer to GD-327, Guidance for Nuclear Criticality Safety [1], Appendix C.
Bias shall be established by correlating the results of critical and exponential experiments with results obtained for these same systems by the calculational method being validated.
When no experimental data are available, establishment of the bias for a calculational method is not possible and the requirements of this section cannot be satisfied. Validation of a calculational method by comparing the results with those of another calculational method, for example, is unacceptable.
The uncertainty in the bias shall contain allowances for uncertainties in the experimental conditions, for lack of accuracy and precision in the calculational method, and for extension of the area (or areas) of applicability. After allowances are made for the accuracy and precision of the method and for the bias and uncertainty, a margin in the keff or other correlating parameter shall be applied that is sufficiently large to ensure that conditions (calculated by the method to be subcritical by this margin) will actually be subcritical. Like the bias and its uncertainty, this margin may vary with composition and other variables.
If the calculational method involves a computer program, checks shall be performed to confirm that the mathematical operations are performed as intended. Any changes in the computer program shall be followed by reconfirmation that the mathematical operations are performed as intended.
A written report of the validation shall be prepared. This report shall:
If single- and multi-parameter limits for 233U, 235U, and plutonium given in sections 2.4 and 2.5 of GD-327, Guidance for Nuclear Criticality Safety [1] are used, an adequate administrative margin of subcriticality shall be applied to ensure compliance with section 2.3.2.2.
In most operations with fissionable materials the risk of inadvertent criticality is very low; however, this risk cannot be eliminated. Where a criticality accident may lead to an excessive radiation dose, it is important to provide a means of alerting personnel and a procedure for their prompt evacuation, or other protective actions to limit their exposure to radiation.
Section 3 (this section) applies to all operations involving fissionable materials in which inadvertent criticality can occur and cause personnel to receive an excessive radiation dose.
The purpose of an alarm system is to reduce risk to personnel. Evaluation of the overall risk should recognize that hazards may result from false alarms and subsequent sudden interruption of operations and relocation of personnel.
Subject to the evaluation of the overall risk described above, a criticality alarm system meeting the requirements of this regulatory document shall be installed in areas where:
Where alarm systems are installed, emergency procedures shall be maintained. Information on the preparation of emergency plans is provided in section 16.
3.3.2.1 Evaluation of criticality alarm systems
In view of the requirement of item 1 in section 3.3.1, the need for criticality alarm systems shall be evaluated:
This evaluation shall be performed for all activities in which the inventory of fissionable materials in individual unrelated areas exceeds the subcritical mass limits noted above.
For this evaluation, individual areas may be considered unrelated when the boundaries between the areas are such that there can be no transfer of materials between areas [9], the minimum separation between material in adjacent areas is 10 cm, and the areal density of fissile material averaged over each individual area is less than 50 g/m2. This stipulation applies only to 233U, 235U, and 239Pu.
3.3.2.2 Installation of criticality alarm systems
A criticality alarm system meeting the requirements of this section shall be installed in areas where personnel would be subject to an excessive radiation dose. For this purpose, the maximum fission yield integrated over the duration of the accident may be assumed not to exceed 2.0 x 1019 fissions. The basis for a different maximum fission yield shall be documented.
If criticality accidents of lesser magnitude than the minimum accident of concern given in section 3.4.3 are of concern, then other detection methods (e.g., audible personnel dosimetry) should be considered. These other detection methods are not considered to be criticality alarm systems and are not covered by section 3 of this regulatory document.
3.3.2.3 Detection of criticality accidents
In areas in which criticality alarm coverage is required, a means shall be provided to detect a criticality accident and to signal that prompt protective action is required.
Criticality alarm signals shall be for prompt evacuation or other protective actions. The criticality alarm signals should be uniform throughout the system. The signals shall be distinctive from other signals or alarms that require a response different from the response necessary in the event of a criticality accident.
The signal generators shall be automatically and promptly actuated upon detection of a criticality accident.
After actuation, the signal generators shall continue to function as required by emergency procedures, even if the radiation falls below the alarm point, and at least long enough to allow people to reach their evacuation assembly points and perform the procedures to account for all personnel. Manual resets, with limited access, should be provided outside areas that require evacuation [9].
A means for manual actuation of the criticality alarm signal may be provided.
For all occupied areas where personnel protective action is required in the event of criticality accident detection, the number and placement of criticality alarm signal generators shall be such that the signals are adequate to notify personnel promptly throughout those areas.
Consideration shall be given to the avoidance of false alarms. This may be accomplished by providing reliable single detector channels or by requiring concurrent response of two or more detectors to initiate the alarm.
In redundant systems, failure of any single channel shall not prevent compliance with the detection criterion specified in section 3.4.3.
Where portable instruments are used to meet the intent of section 3 of this regulatory document, the usage shall be evaluated to determine appropriate criteria are met. Criteria for such use of portable instruments shall be specified in procedures.
Process areas in which activities will continue during power outages shall have emergency power supplies for alarm systems, or such activities shall be monitored continuously with portable instruments.
Adequate sensitivity of the alarm system to respond to the minimum accident of concern is addressed in section 3.4.4.
Detectors shall not fail to trigger an alarm when subjected to intense radiation exceeding 1000 Gy/h. Compliance with this provision may be demonstrated by a test of sample detectors or by a manufacturer’s test of production samples [9].
The system shall be designed for high reliability and should use components that do not require frequent servicing (such as lubrication or cleaning).
The system shall be designed to produce the criticality alarm signal within one half-second (0.5 s) of detector recognition of a criticality accident.
Criticality alarm systems shall be designed to respond immediately to the minimum accident of concern. In situations where there is only nominal shielding, the definition of minimum accident of concern provided in the glossary should be used. The basis for a different definition of minimum accident of concern shall be documented.
Criticality alarm systems shall be designed so that alarm actuation shall occur as a result of the minimum duration transient. It may be assumed that the minimum duration of the radiation transient is one millisecond (1 ms).
The alarm trip point shall be set low enough to detect the minimum accident of concern. The alarm trip point should be set high enough to minimize the probability of an alarm from sources other than criticality.
The spacing of detectors shall be consistent with the selected alarm trip point and with the detection criterion.
Initial tests, inspections, and checks of the system shall verify that the fabrication and installation were made in accordance with design plans and specifications.
Following modifications or repairs, or events that call the system performance into question, there shall be tests and inspections adequate to demonstrate system operability.
System response to radiation shall be measured periodically to confirm continuing instrument performance. The test interval should be determined on the basis of experience. In the absence of experience, tests should be performed at least monthly.
Records of tests shall be maintained. System designs may incorporate self-checking features to automate portions of this testing.
The entire alarm system shall be tested periodically. Each signal generator should be tested at least annually. Field observations shall establish that criticality alarm signals are functional throughout all areas where personnel could be subject to an excessive radiation dose. All personnel in affected areas shall be notified before testing of the criticality alarm signals.
When tests reveal inadequate performance, corrective action shall be taken without unnecessary delay. If portable instrument use is required, the criteria of section 3.3.4 shall be met.
Procedures for system testing shall minimize both false alarms and inadvertent initiation of emergency response. The procedures shall require that the systems be returned to normal operation immediately following tests.
The IEC 860 Standard, Warning Equipment for Criticality Accidents [11], holds useful information regarding electrical characteristics and testing procedures for alarm equipment. This document may be used as a guide in these areas.
Records of tests and corrective actions for each system shall be maintained.
The licensee shall develop and implement out-of-service criteria for the nuclear criticality alarm system.
If the system is removed from service due to an unforeseen problem, the licensee shall immediately inform CNSC as to the cause of the removal and its expected duration.
Instructions regarding response to criticality alarm signals shall be posted at strategic locations within areas requiring alarm coverage.
The purpose of Raschig rings in criticality safety applications is to assure subcriticality for normal and credible abnormal conditions over the operating life of a vessel. General requirements for use of Raschig rings for criticality control are:
For additional safety information and guidance on the use of borosilicate-glass Raschig rings as a neutron absorber for criticality control in ring-packed vessels containing solutions of 235U, 239Pu, or 233U, refer to section 4 of GD-327, Guidance for Nuclear Criticality Safety [1].
Personnel protection during in situ experiments depends on the avoidance of a criticality accident. Safety criteria and practices for conducting such experiments shall be followed.
For additional safety information and guidance on conducting subcritical neutron-multiplication measurements where physical protection of personnel against the consequences of a criticality accident is not provided, refer to section 5 of GD-327, Guidance for Nuclear Criticality Safety [1].
All operations with fissile material, including storage, shall be conducted in accordance with section 2. If the limits given in section 6 of GD-327, Guidance for Nuclear Criticality Safety [1] are used, an adequate administrative margin of subcriticality shall be applied to ensure compliance with section 2.3.2.2.
For additional safety information and guidance on general storage criteria based on validated calculations, refer to section 6 of GD-327, Guidance for Nuclear Criticality Safety [1]. GD-327 includes additional engineering and administrative practices appropriate to the storage of fissile material.
If adequate shielding against radiation and confinement of radioactive materials are provided, the hazards normally attendant with criticality in a facility lacking shielding and confinement are minimized.
This section applies to operations, with 235U, 233U, 239Pu and other fissile and fissionable materials outside of nuclear reactors, in which shielding and confinement are provided for protection of personnel and the public, except the assembly of these materials under controlled conditions, such as in critical experiments. Criteria for criticality control under these conditions shall be provided for:
This section does not apply to those operations requiring entry of personnel inside the shielded process areas wherein fissile and fissionable materials are contained. This section does not include engineering specifications for shield design nor for establishing its adequacy. Nothing in this section shall be interpreted as discouraging additional safety features that can be conveniently incorporated.
This section does not include the details of administrative procedures for control (which are considered to be management prerogatives) or details regarding the design of processes and equipment or descriptions of instrumentation for process control.
For additional safety information and guidance, refer to section 7 of GD-327, Guidance for Nuclear Criticality Safety [1].
This section applies to operations with plutonium-uranium oxide fuel mixtures outside nuclear reactors, except the assembly of these materials under controlled conditions, such as in critical experiments.
Operations within the scope of this section shall be conducted in accordance with section 2. If the limits for plutonium-uranium mixtures given in section 8 of GD-327, Guidance for Nuclear Criticality Safety [1] are used, an adequate administrative margin of subcriticality shall be applied to ensure compliance with section 2.3.2.2. Attention shall be given to credible abnormal conditions such as those listed in Appendix A.
The administrative and technical practices for criticality safety and control as described in section 12 are applicable herein.
For additional guidance, refer to section 8 of GD-327, Guidance for Nuclear Criticality Safety [1].
The use of soluble neutron absorbers for criticality accident prevention shall be conducted in accordance with section 2.
For guidance on the use of soluble neutron absorbers for criticality control, neutron absorber selection, system design and modifications, safety evaluations, and quality assurance programs, refer to section 9 of GD-327, Guidance for Nuclear Criticality Safety [1].
This section applies to operations with the following: 23793Np, 23894Pu, 24094Pu, 24194Pu, 24294Pu, 24195Am, 242m95Am, 24395Am, 24396Cm, 24496Cm, 24596Cm, 24796Cm, 24998Cf, and 25198Cf.
Operations within the scope of this section shall be conducted in accordance with section 2. If the limits given in section 10 of GD-327, Guidance for Nuclear Criticality Safety [1] are used, an adequate administrative margin of subcriticality shall be applied to ensure compliance with section 2.3.2.2. Attention shall be given to credible abnormal conditions such as those listed in Appendix A.
The administrative and technical practices for criticality safety and control as described in section 12 are applicable herein.
For additional guidance, refer to section 10 of GD-327, Guidance for Nuclear Criticality Safety [1].
The handling, transportation, storage, and long-term waste management of fuel for nuclear reactors represents a health and safety risk to personnel involved in these activities, as well as to the general public. Within the boundaries of the licensed site, appropriate design of equipment and facilities, handling procedures, and personnel training can minimize this risk.
Operations within the scope of this section shall be conducted in accordance with section 2.
For information related to the transportation of fissile material outside the licensed site, refer to the Packaging and Transport of Nuclear Substances Regulations, the IAEA safety guide Regulations for the Safe Transport of Radioactive Material (TS-R-1)[14], the associated guidance document Advisory Material for the IAEA Regulations for the Safe Transport of Radioactive Material (TS-G-1.1)[15], and RD-364 Joint Canada—United States Guide for Approval of Type B(U) and Fissile Material Transportation Packages [16].
For additional guidance applicable to handling, transportation, storage, and long-term waste management of reactor fuel units in any phase of the fuel cycle outside the reactor core and within the boundaries of the licensed site, refer to section 11 of GD-327, Guidance for Nuclear Criticality Safety [1].
Although the extent and complexity of safety-related activities may vary greatly with the size and type of operation with fissionable material, certain safety elements are common. This section represents a codification of such elements related to criticality safety.
This section provides criteria for the administration of a nuclear criticality safety program for operations outside reactors for which there exists a potential for criticality accidents.
Responsibilities of management, supervision, and the nuclear criticality safety staff are addressed. Objectives and characteristics of operating and emergency procedures are included.
General requirements for nuclear criticality safety can be found in section 2.
Management shall:
Management may use consultants and nuclear criticality safety committees to achieve the objectives of the nuclear criticality safety program.
Each supervisor shall:
The nuclear criticality safety staff (NCS staff) shall:
The purpose of written operating procedures is to facilitate and document the safe and efficient conduct of the operation. Procedures should be organized for convenient use by operators and be easily available. They should be free of extraneous material. Copies of applicable written procedures should be posted up or available in operating areas [8].
Procedures shall include those controls and limits significant to nuclear criticality safety. Procedures should be such that no single inadvertent departure from a procedure can cause a criticality accident.
Supplementing and revising procedures, as improvements become desirable, shall be facilitated.
Operating procedures shall be reviewed periodically by supervisory personnel.
New or revised procedures that affect nuclear criticality safety shall be reviewed by the NCS staff and by the supervisory personnel, and shall be approved by management [10].
Deviations from operating procedures and unforeseen alterations in process conditions that affect nuclear criticality safety shall be reported to management, investigated promptly, corrected as appropriate, and documented. Action shall be taken to prevent a recurrence.
Operations shall be reviewed frequently (at least annually) to ascertain that procedures are being followed and that process conditions have not been altered so as to affect the Nuclear Criticality Safety Evaluation (NCSE). These reviews shall be conducted, in consultation with operating personnel, by individuals who are knowledgeable in criticality safety and who, to the extent practicable, are not immediately responsible for the operation.
Before the start of a new operation with fissionable material, or before an existing operation is changed, it shall be determined and documented that the entire process is subcritical under both normal and credible abnormal conditions.
The NCSE shall determine and explicitly identify the controlled parameters and their associated limits upon which nuclear criticality safety depends. The effect of changes in these parameters, or in the conditions to which they apply, shall be understood.
The NCSE shall be documented with sufficient detail, clarity, and lack of ambiguity to allow independent judgment of results.
Before the start of operation, there shall be an independent assessment that confirms the adequacy of the NCSE.
The movement of fissionable materials shall be controlled as specified in documented procedures. The transport of fissionable materials within the public domain shall comply with appropriate national and international regulations [10,14,15,16].
Appropriate material labelling and area posting shall be maintained, specifying material identification and all limits on parameters that are subject to procedural criticality control.
If reliance for criticality control is placed on neutron-absorbing materials that are incorporated into process materials or equipment, procedural control shall be exercised to maintain their continued presence with the intended distributions and concentrations.
Access to areas where fissionable material is handled, processed, or stored shall be controlled.
Control of spacing, mass, density, and geometry of fissionable material shall be maintained to assure subcriticality under all normal and credible abnormal conditions (note: this requirement is not applicable to operations with a small quantity of fissionable materials).
Nuclear criticality accident alarm systems are addressed in section 3. Emergency planning and response are addressed in section 16.
Emergency procedures shall be prepared, and shall be approved by management. Organizations on- and off-site, that are expected to provide assistance during emergencies, shall be informed of conditions that might be encountered. They should be assisted in the preparation of suitable emergency response procedures.
Emergency procedures shall clearly designate evacuation routes. Evacuation should follow the quickest and most direct routes practicable. These routes shall be clearly identified and should avoid recognized areas of higher risk.
Personnel assembly stations, outside the areas to be evacuated, shall be designated. Means to account for personnel shall be established.
Personnel in the area to be evacuated shall be trained in evacuation methods and informed of evacuation routes and assembly stations. Provision shall be made for the evacuation of transient personnel. Drills shall be performed at least annually to maintain familiarity with the emergency procedures. Drills shall be announced in advance.
Arrangements shall be made in advance for the care and treatment of injured and exposed persons. The possibility of personnel contamination by radioactive materials shall be considered.
Planning shall include a program for the immediate identification of exposed individuals and should include personnel dosimetry. Guidance for dosimetry can be found in the ANSI publication N13.3-1969, Dosimetry for Criticality Accidents [17].
Instrumentation and procedures shall be provided for the determination of the radiation intensity at the assembly area and in the evacuated area following a criticality accident. Information should be correlated at a central control point.
Emergency procedures shall address re-entry procedures and the membership of response teams.
Emergency procedures shall provide for shutting off ventilation to prevent release of fission gases outside of affected area. Consideration should be given that shutting off ventilation does not generate other safety hazards.
The nuclear criticality safety program:
For an example of a nuclear criticality safety program, refer to Appendix G of GD-327, Guidance for Nuclear Criticality Safety [1].
Training of employees associated with fissionable material operations outside reactors where potential exists for criticality accidents shall be performed.
For additional guidance on nuclear criticality safety training, refer to section 13 of GD-327, Guidance for Nuclear Criticality Safety [1].
The purpose of fixed neutron absorbers in criticality control applications is to assure sub- criticality for normal and credible abnormal conditions over the operating life of the facility or equipment. For the purposes of this document, fixed neutron absorbers are materials that:
The use of fixed neutron absorbers for criticality control application shall be conducted in accordance with section 2. Verification of the absorbers and their effectiveness to capture neutrons shall be required before the materials are used. After the installation, there shall be verification to ensure that the neutron absorber system is in place as intended.
For additional guidance on the use of fixed neutron absorbers in the design, construction, and operation of nuclear facilities outside reactors, refer to section 14 of GD-327, Guidance for Nuclear Criticality Safety [1].
For many operations, criticality safety is achieved through the limitation of parameters such as geometry, mass, enrichment, and spacing of fissionable materials. The amount of fissionable material that can be safely handled, stored, or processed at one time can also depend on the credible range of neutron moderation. Optimum moderation, by definition, results in the lowest critical mass of fissionable materials, other conditions being unchanged.
Operations within the scope of this section shall be conducted in accordance with section 2. Safety criteria and practices for achieving criticality safety by the limitation and control of moderators in the range from no moderation to optimum moderation for fissionable materials shall be documented and followed.
For additional guidance, refer to section 15 of GD-327, Guidance for Nuclear Criticality Safety [1].
Nuclear criticality safety programs at facilities that use fissionable material are primarily directed at the avoidance of nuclear criticality accidents. However, the possibility of such accidents exists and the consequences can be life-threatening. This possibility mandates advance planning practice in planned emergency responses and verification of readiness.
Criticality accident emergency planning and response procedures shall be maintained in any facility where a criticality accident alarm system, as specified in section 3, is in use. The provisions of this section may be considered in emergency planning for nuclear power plant sites and research reactor facilities. This section does not apply to off-site accidents, or to off-site emergency planning and response.
For additional guidance on minimizing risks to personnel during emergency response to a nuclear criticality accident outside reactors, refer to section 16 of GD-327, Guidance for Nuclear Criticality Safety [1].
The determination that a process will be subcritical under normal and credible abnormal conditions requires careful study. The criticality accidents that have occurred in industrial operations have resulted from failure to anticipate conditions that might arise; none has resulted from a faulty calculation of keff.
The engineered nuclear criticality safety controls should be designed to withstand the effects of extreme loadings and environmental conditions (for example, extremes of temperature, humidity, pressure, or radiation) arising from the following initiating conditions and any other conditions having a direct effect on nuclear criticality safety [2]:
The following are typical examples of variations in process conditions that should be considered:
Where calculational methods of analysis are applied to predict neutron multiplication factors for safety assessments, the calculated multiplication factor, kp, for that application, plus its associated uncertainties, |∆kp|, shall not exceed an established allowable value (the upper subcritical limit (USL)) for the neutron multiplication factor for all normal and credible abnormal conditions as follows:
kp + |∆kp| ≤ USL
In these calculations, USL is the result of the validation process and may be expressed as:
USL = kc - |∆kc| - |∆km|
where:
kc |
= |
the mean keff, which results from the calculation of the benchmark criticality experiments through the use of a particular calculational method. If the calculated multiplication factors for the criticality experiments exhibit a trend with a parameter, then kc shall be determined on the basis of a best fit to the calculated values. The experiments used as benchmarks in computing kc should have material compositions (fissionable materials, neutron absorbers, and moderators), geometric configurations, neutron energy spectra, and nuclear characteristics (including reflectors) similar to those of the system being evaluated. The difference between the experimentally measured value of keff and kc is defined as the bias. This bias is expected to be a function of composition and other variables and should be examined for trends. |
∆kc |
= |
a margin for kc bias and bias uncertainty, which includes allowance for:
|
∆km |
= |
a minimum administrative margin of 50 mk to ensure the subcriticality of USL. |
kp |
= |
the calculated multiplication factor, keff, of the system being evaluated for normal and credible abnormal conditions or events. |
∆kp |
= |
an allowance for:
|
The various uncertainties may be combined statistically if they are independent (an example of this can be found in [18]). Correlated uncertainties should be combined additively.
Methods that do not directly yield keff, but whose validity has been established in accordance with section 2, may be used to ensure subcriticality.
Appropriate experimental data or data derived from experiments, with an allowance adequate to ensure subcriticality, may be used directly.
In situ measurements performed in accordance with section 5 may be used to confirm subcriticality.
Example
For all normal and credible abnormal conditions, the following condition is to be demonstrated:
kp + 2σ ≤ USL
Where kp is the calculated multiplication factor, σ is its statistical or convergence uncertainty, and USL is the established upper subcritical limit.
ANS |
American Nuclear Society |
ANSI |
American National Standards Institute |
ASME |
American Society of Mechanical Engineers |
CSA |
Canadian Standards Association |
CSC |
criticality safety control |
IAEA |
International Atomic Energy Agency |
NCS |
nuclear criticality safety |
NCSE |
nuclear criticality safety evaluation |
NCS staff |
nuclear criticality safety staff |
QM |
quality management |
USL |
upper subcritical limit |